PHASES |
1x |
|
VOLTAGE |
230 V |
|
CURRENT |
14 A |
|
POWER |
3300 W |
|
MAX. AIR OUTLET TEMPERATURE |
650 degree C |
|
MIN. AIR FLOW |
260 l per min |
|
MAX. AIR INLET TEMPERATURE |
65 degree C |
|
MAX. AMBIENT TEMPERATURE |
65 degree C |
|
AIR TEMPERATURE CONTROL |
Open loop |
|
OVERHEATING PROTECTION |
Yes |
|
ALARM OUTPUT |
Normally open contact |
|
MAX. INLET PRESSURE |
100 kPa |
|
NOZZLE CONNECTION |
36.5 mm per 1.45 in |
|
DISPLAY |
No |
|
LENGTH |
266.0 mm |
|
WIDTH |
67.0 mm |
|
HEIGHT |
71.0 mm |
|
WEIGHT |
0.65 kg |
Price:
![]() |
LEISTER TECHNOLOGIES INDIA PVT. LTD.